Double Nozzle

From the experiment:
◆ When the flux of 0.8m2 membrane element is set to 600L/(m2·d), the transmembrane pressure difference is equivalent to that when the flux of 1.5m2 membrane element is set to 400L/(m2·d);
◆ Under the same water quality conditions, the flux of 0.8m2 membrane element can be selected to 400~500L/(m²·d).

Model 1.5m² 0.8m²*2
Water temperature 25°C
Test time Three(15min)
Vacuum degree(Kpa) -10
Flow(L/h) 75.2 75.1 75.4 108.2 107.8 108.0
Average flow(L/h) 75.2 108.0
Membrane flux(L/m²·h) 50.1 67.5
Daily traffic(L/m²·d) 1202.4 1620.0